This e-mail address is protected from spam bots. You need JavaScript enabled to view.

Air Traffic Control Consoles: How to Plan a Hall and Create a Technical Specification

Consoles in control towers or ATM centers are replaced every 10-15 years, and errors in the technical specifications are then tolerated for all those years. In this article, we explore the differences between consoles for different ATC services, how to plan a conference room, and what must be included in the technical specifications in 2026 to ensure the consoles are right the first time.

One remote control won't work for all services.

The term "air traffic controller console" encompasses very different workspaces. A tower controller stares out a window, a district center dispatcher works in a darkened room with radar screens, and a PDSP employee spends most of their shift talking on the phone. Therefore, the project should begin not with a catalog, but with the question of which service will be seated at the console.

ServiceWorking conditionsWhat does this mean for the remote?
Control tower controller (CDP, tower dispatcher)Visual control of the airfield through glazing, bright daylightLow profile console and monitors to avoid obstructing the view; matte surfaces for low glare
Approach and Area Center Controller (ATM)Darkened room, working with radar information for several hours straightLarge monitors at eye level, local keyboard backlighting, dark, non-reflective desk tops
Control tower of international flights, small airfields1-2 workstations, often combining functionsA compact console that combines communications, weather, and monitoring in one place.
PDSP, VSDP, platform dispatchersLots of telephone and radio communication, work with documentsWork area for papers, space for telephones and radios, convenient access to office equipment
ASSStandby mode and quick transition to active actionsDirect access to notification buttons and communication tools, simple layout

Hall layout: where to start

The console is designed in conjunction with the room. If you buy consoles first and then plan their placement, you almost always find that they don't fit through the door, block the view, or interfere with servicing the equipment.

Control tower

The tower is typically polygonal, and the consoles are positioned along the glass in a semicircle or ring. The main limitation is height. The top edge of the monitors and superstructures must not obstruct the controller's line of sight to the runway and taxiways. This angle should be verified on a 3D model before production; redesigning an existing console is much more expensive.

District center or approach hall

Here, consoles are arranged in rows or sectors, with a video wall often located behind them. It's important that the video wall be readable from every seat without having to turn more than 30-40 degrees, and that adjacent dispatchers don't obstruct each other's view. A passageway is left between rows large enough to allow one to get up and exit without bumping into a colleague.

Access for maintenance

System units, switches, and power supplies inside the console must be accessible without interrupting the dispatcher's work. The best option is servicing from the rear or through removable panels. If the console is located close to a wall or glass, this must be taken into account in advance.

Practical advice: Ask the manufacturer for a 3D model of the room with seating and people. It will immediately show where it will be crowded, where the light is falling, and whether anything is blocking the view.

Light, noise and heat: what is often overlooked

  • Glare. Glossy surfaces reflect light from windows and screens. For towers and radar rooms, matte countertops and anti-glare monitors are preferred.
  • Lighting of the work area. In a darkened room, the dispatcher needs local backlighting for the keyboard and documents with adjustable brightness, otherwise the eyes get tired from changes in light.
  • Noise from equipment. Multiple system units in a single console produce a noticeable hum. A closed compartment and quiet fans reduce the noise, which directly impacts radio intelligibility.
  • Overheat. If a compartment isn't ventilated, the equipment operates at its limits and breaks down more often. The equipment's heat output should be specified in the specifications so the manufacturer can calculate the required ventilation.
  • Static electricity. For rooms with a lot of electronics, it makes sense to request an anti-static frame coating and grounding.

Cables and communications

The air traffic control console is where power lines, network, radio communications, telephone, and signal cables converge. If all of this is housed in a single channel, the risk of interference and confusion during repairs increases. Therefore, power and low-current lines are routed through separate cable channels, and cable entry is coordinated with the raised floor or cable trays in the room.

Consider carefully the placement of radio consoles, headsets, footswitches, and telephones. Their placement depends on which hand the dispatcher uses the mouse and how often they communicate.

Modernization without stopping the air traffic control department

Stopping air traffic control to replace furniture is unacceptable. Therefore, the modernization of the existing hall is planned in stages:

  1. During the work, reserve workstations are organized in an adjacent room or on part of the old consoles.
  2. New remote controls are replaced in groups, starting with the least loaded positions.
  3. Cable routes are prepared in advance so that equipment relocation takes hours rather than days.
  4. Installation is scheduled for periods with minimal flight intensity, most often at night.
  5. After each stage, dispatchers work in new locations and provide feedback that can be incorporated into subsequent consoles.

Checklist for technical specifications

The more precise the specifications, the fewer post-delivery revisions. Here's what you should include:

  • Service and operating mode. What positions, how many shifts, is it open 24 hours?
  • Number of jobs and the ability to combine consoles into a single complex.
  • Equipment. The number and diagonal of monitors, system units, unit equipment, communication equipment, their dimensions and heat dissipation.
  • Premises. Plan with dimensions, doorways, glazing, raised floor, location of sockets and cable entries.
  • Ergonomics. Do you need adjustable tabletop height, standing work, lighting, or noise-insulating screens?
  • Materials. Requirements for fire resistance, resistance to disinfection and wear, color of the frame and countertops.
  • Installation. Deadlines, schedule of access to the site, requirements for the access control system.
  • Documentation. Certificates, product passport, and inclusion in the Russian Ministry of Industry and Trade's product register, if relevant for procurement.

How is this solved in practice?

When designing a console for Manas Airport ( a project for the Kyrgyzaeronavigatsia State Enterprise ), the client prioritized quiet operation and equipment protection. Therefore, the console features a ventilated technical compartment with a removable floor, electrically operated noise barriers, and separate cable ducts. DISSOL also uses this approach in its SETERA serial consoles , and ready-made solutions are available in the Air Traffic Control Consoles section.

Don't forget about the surrounding area. The 24/7 desk chair and monitor mounts can contribute to dispatcher fatigue just as much as the console itself.

Send us your room plan and equipment list, and we'll create a 3D design of your air traffic control console specifically for your facility.

Send technical specifications

Questions and Answers

How long does an air traffic control console last?

With a metal frame and wear-resistant tabletops, the console lasts 10-15 years. It's usually replaced not due to wear and tear, but rather when equipment is upgraded or the room is renovated.

Is it possible to install new hardware in old consoles?

Sometimes yes, but older consoles are often not designed for multiple monitors, modern heat dissipation, and cable volume. If the ATC system is replaced, it's more cost-effective to replace the furniture at the same time.

How long does it take to produce?

The timeframe depends on the number of seats and the complexity of the configuration. It includes design, 3D model approval, production, and installation. We will provide a precise timeframe after receiving the specifications.

Is it necessary to adjust the height of the table top?

If different people work at the same station in shifts, adjusting the height can significantly reduce back and neck strain. For towers, ensure that monitors don't obstruct the view when raised.

How is an air traffic controller's console different from a regular control desk?

The main differences are a closed, ventilated compartment for equipment, the integration of radio communications equipment, increased material requirements, and the need to take into account the view from the tower window. We wrote about this in more detail in our article on the differences between traditional and aviation control room furniture.

News

  • Control Center Equipment: What It Includes and How to Plan It

    Control Center Equipment: What It Includes and How to Plan It

  • Air Traffic Control Consoles: How to Plan a Hall and Create a Technical Specification

    Air Traffic Control Consoles: How to Plan a Hall and Create a Technical Specification

  • Dispatch Chair: Design, Standards, and Selection for 24/7 Operation

    Dispatch Chair: Design, Standards, and Selection for 24/7 Operation

  • Control desk: design, types and requirements for the operator's workstation

    Control desk: design, types and requirements for the operator's workstation

  • What is a situation center and what furniture is needed?

    What is a situation center and what furniture is needed?

  • Railway dispatcher's console: furniture for railway control rooms

    Railway dispatcher's console: furniture for railway control rooms

  • Oil and Gas Facility Dispatcher Workstation: Requirements, Specifics, and Professional Solutions

    Oil and Gas Facility Dispatcher Workstation: Requirements, Specifics, and Professional Solutions

  • What is the difference between classic control room furniture and aviation control room furniture solutions?

    What is the difference between classic control room furniture and aviation control room furniture solutions?

  • How to distinguish original professional control room furniture from DISSOL Company from a fake

    How to distinguish original professional control room furniture from DISSOL Company from a fake

Moscow
Your region: Moscow